Vertiq 40-06 370Kv

T-Motor P14x4.8R

Philadelphia, PA USA | 15m | 2023-05-30 | 22.7 C | 30.18 in Hg | 39.5 %

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Speed (RPM) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W) State of Operation
2.0 24.0 0.1 1 710 0.00 20.3 10 7.7 Continuous
4.0 24.0 0.2 4 1430 0.01 55.1 60 16.0 Continuous
6.0 24.0 0.4 9 2130 0.03 73.5 150 16.0 Continuous
8.0 23.9 0.8 20 2800 0.06 81.9 270 13.7 Continuous
10.0 23.9 1.5 35 3450 0.08 86.1 420 11.8 Continuous
12.0 23.9 2.4 57 4060 0.12 87.7 590 10.4 Continuous
14.0 23.8 3.5 84 4620 0.15 88.2 790 9.4 Continuous
16.0 23.8 4.9 116 5140 0.19 88.2 990 8.5 Continuous
18.0 23.7 6.5 153 5600 0.23 87.2 1190 7.8 Continuous
20.0 23.7 8.2 194 6030 0.26 86.2 1380 7.1 Continuous
22.0 23.6 10.1 237 6430 0.30 84.9 1570 6.6 Continuous
24.0 23.5 11.4 268 6640 0.32 83.5 1690 6.3 Continuous

All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous" region should not cause motor or ESC overheating when using the Default or Pro Kits.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the Performance Kit.
Performance in the "Continuous*" region is classified as intermittent when not using the Performance Kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.