Vertiq 60-08 150Kv

G27x8.8R

Philadelphia, PA USA | 15m | 27.0 C | 29.95 in Hg | 38.1% Humidity

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Speed (RPM) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W) State of Operation
2.0 24.1 0.1 2 260 0.02 35.8 30 16.2 Continuous
4.0 24.1 0.2 5 520 0.06 62.9 120 23.5 Continuous
6.0 24.1 0.5 13 780 0.12 75.2 290 22.4 Continuous
8.0 24.1 1.1 28 1040 0.20 79.8 530 19.3 Continuous
10.0 24.1 2.1 50 1290 0.30 82.2 840 16.8 Continuous
12.0 24.0 3.3 80 1540 0.41 83.2 1200 15.0 Continuous
14.0 24.0 5.0 120 1770 0.54 83.1 1570 13.0 Continuous
16.0 24.0 7.0 168 1990 0.67 82.8 1970 11.7 Continuous
18.0 23.9 9.4 225 2190 0.80 81.9 2420 10.8 Continuous
20.0 23.8 12.1 289 2380 0.94 80.9 2830 9.8 Continuous
22.0 23.8 15.2 361 2560 1.07 79.8 3260 9.0 Continuous*
24.0 23.7 18.1 428 2670 1.19 78.0 3670 8.6 Continuous*

All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous" region should not cause motor or ESC overheating when using the Default or Pro Kits.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the Performance Kit.
Performance in the "Continuous*" region is classified as intermittent when not using the Performance Kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.