Vertiq 60-08 300Kv

P17x5.8R 24V

Philadelphia, PA USA | 15m | 2024-08-09 | 25.9 C | 29.77 in Hg | 57.6% Humidity

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Speed (RPM) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W) State of Operation
2.0 24.2 0.1 2 510 0.01 15.1 20 9.4 Continuous
4.0 24.2 0.3 7 1090 0.02 36.9 90 13.7 Continuous
6.0 24.2 0.6 15 1680 0.05 55.0 200 13.1 Continuous
8.0 24.2 1.2 30 2260 0.08 65.5 370 12.3 Continuous
10.0 24.1 2.2 53 2840 0.13 74.8 610 11.4 Continuous
12.0 24.1 3.7 89 3400 0.20 80.2 930 10.5 Continuous
14.0 24.1 5.6 135 3950 0.27 83.0 1290 9.6 Continuous
16.0 24.0 8.1 195 4490 0.36 86.4 1740 8.9 Continuous
18.0 23.9 11.1 266 5000 0.44 87.2 2180 8.2 Continuous
20.0 23.9 14.7 351 5510 0.53 87.9 2640 7.5 Continuous
22.0 23.8 19.0 451 5980 0.63 88.2 3140 7.0 Continuous
24.0 23.7 22.5 532 6320 0.71 87.8 3500 6.6 Continuous

All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the performance kit.
Performance in the "Continuous*" region is classified as intermittent when not using the performance kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.