Vertiq 60-08 300Kv

P18x6.1R 24V

Philadelphia, PA USA | 15m | 2024-08-09 | 26.1 C | 29.78 in Hg | 48.9% Humidity

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Speed (RPM) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W) State of Operation
2.0 24.2 0.1 2 0 0.01 0.0 10 4.0 Continuous
4.0 24.2 0.3 7 510 0.03 19.1 90 12.1 Continuous
6.0 24.2 0.8 19 1080 0.06 38.2 240 12.9 Continuous
8.0 24.1 1.6 40 1670 0.12 52.5 490 12.3 Continuous
10.0 24.1 3.0 72 2240 0.19 60.9 810 11.2 Continuous
12.0 24.1 5.0 119 2800 0.27 66.7 1210 10.1 Continuous
14.0 24.0 7.5 181 3350 0.36 70.8 1650 9.1 Continuous
16.0 23.9 10.8 258 3880 0.47 73.5 2140 8.3 Continuous
18.0 23.9 14.7 350 4390 0.58 75.6 2670 7.6 Continuous
20.0 23.7 19.4 461 4870 0.70 77.2 3220 7.0 Continuous
22.0 23.6 24.6 581 5320 0.82 78.2 3780 6.5 Continuous
24.0 23.5 28.4 669 5750 0.89 80.5 4130 6.2 Continuous

All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous" region should not cause motor or ESC overheating when using the Default or Pro Kits.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the Performance Kit.
Performance in the "Continuous*" region is classified as intermittent when not using the Performance Kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.