Vertiq 60-08 300Kv

P20x6R 24V

Philadelphia, PA USA | 15m | 2024-08-05 | 27.7 C | 29.97 in Hg | 48.7% Humidity

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Speed (RPM) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W) State of Operation
2.0 24.2 0.1 3 510 0.01 26.1 50 19.6 Continuous
4.0 24.2 0.4 9 1070 0.04 52.3 140 16.3 Continuous
6.0 24.2 0.9 23 1650 0.09 67.1 330 14.6 Continuous
8.0 24.1 2.0 49 2220 0.16 75.7 610 12.4 Continuous
10.0 24.1 3.8 91 2760 0.26 81.2 1030 11.3 Continuous
12.0 24.0 6.4 153 3280 0.38 84.2 1550 10.1 Continuous
14.0 24.0 9.7 233 3780 0.50 84.6 2080 8.9 Continuous
16.0 23.8 14.0 334 4240 0.63 84.2 2670 8.0 Continuous
18.0 23.7 19.0 450 4680 0.77 83.5 3250 7.2 Continuous
20.0 23.6 24.8 584 5080 0.91 83.3 3870 6.6 Continuous
22.0 23.4 31.3 735 5440 1.06 82.2 4490 6.1 Continuous*
24.0 23.4 34.9 815 5610 1.13 81.3 4780 5.9 Continuous*

All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous" region should not cause motor or ESC overheating when using the Default or Pro Kits.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the Performance Kit.
Performance in the "Continuous*" region is classified as intermittent when not using the Performance Kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.