Vertiq 60-08 300Kv
P20x6R 24V
Philadelphia, PA USA | 15m | 2024-08-05 | 27.7 C | 29.97 in Hg | 48.7% Humidity
Commanded Voltage (V) | Supply Voltage (V) | Supply Current (A) | Input Power (W) | Torque (Nm) | Motor-Controller Efficiency (%) | Thrust (g) | Propulsion Efficiency (g/W) | Speed (RPM) | State of Operation |
---|---|---|---|---|---|---|---|---|---|
2.0 | 24.2 | 0.1 | 3 | 0.01 | 26.1 | 50 | 19.6 | 510 | Continuous |
4.0 | 24.2 | 0.4 | 9 | 0.04 | 52.3 | 140 | 16.3 | 1070 | Continuous |
6.0 | 24.2 | 0.9 | 23 | 0.09 | 67.1 | 330 | 14.6 | 1650 | Continuous |
8.0 | 24.1 | 2.0 | 49 | 0.16 | 75.7 | 610 | 12.4 | 2220 | Continuous |
10.0 | 24.1 | 3.8 | 91 | 0.26 | 81.2 | 1030 | 11.3 | 2760 | Continuous |
12.0 | 24.0 | 6.4 | 153 | 0.38 | 84.2 | 1550 | 10.1 | 3280 | Continuous |
14.0 | 24.0 | 9.7 | 233 | 0.50 | 84.6 | 2080 | 8.9 | 3780 | Continuous |
16.0 | 23.8 | 14.0 | 334 | 0.63 | 84.2 | 2670 | 8.0 | 4240 | Continuous |
18.0 | 23.7 | 19.0 | 450 | 0.77 | 83.5 | 3250 | 7.2 | 4680 | Continuous |
20.0 | 23.6 | 24.8 | 584 | 0.91 | 83.3 | 3870 | 6.6 | 5080 | Continuous |
22.0 | 23.4 | 31.3 | 735 | 1.06 | 82.2 | 4490 | 6.1 | 5440 | Continuous* |
24.0 | 23.4 | 34.9 | 815 | 1.13 | 81.3 | 4780 | 5.9 | 5610 | Continuous* |
All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the performance kit.
Performance in the "Continuous*" region is classified as intermittent when not using the performance kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.