Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Speed (RPM) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W) State of Operation
2.0 24.2 0.1 3 490 0.02 36.8 60 19.1 Continuous
4.0 24.2 0.6 15 1040 0.09 67.2 280 18.9 Continuous
6.0 24.1 1.9 45 1590 0.21 78.9 680 15.2 Continuous
8.0 24.1 4.2 101 2100 0.38 82.3 1270 12.6 Continuous
10.0 24.0 7.7 185 2570 0.57 82.9 1960 10.6 Continuous
12.0 23.9 12.2 293 2990 0.77 82.3 2680 9.2 Continuous
14.0 23.8 18.0 428 3360 0.98 80.4 3430 8.0 Continuous
16.0 23.6 24.5 579 3690 1.18 78.6 4150 7.2 Continuous*
18.0 23.4 32.3 758 3980 1.37 75.1 4830 6.4 Intermittent

All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous" region should not cause motor or ESC overheating when using the Default or Pro Kits.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the Performance Kit.
Performance in the "Continuous*" region is classified as intermittent when not using the Performance Kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.