Vertiq 60-08 660Kv

P13x4.4R 24V

Philadelphia, PA USA | 15m | 28.1 C | 30.0 in Hg | 48.9% Humidity

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Speed (RPM) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W) State of Operation
2.0 24.2 0.3 6 1170 0.01 14.9 30 4.9 Continuous
4.0 24.1 0.9 22 2510 0.03 37.2 150 6.9 Continuous
6.0 24.1 2.2 53 3840 0.07 54.3 390 7.4 Continuous
8.0 24.1 4.3 103 5150 0.12 65.1 700 6.8 Continuous
10.0 24.0 7.6 181 6430 0.19 71.4 1140 6.3 Continuous
12.0 23.9 12.1 288 7690 0.27 75.8 1650 5.7 Continuous
14.0 23.7 18.2 432 8900 0.36 78.1 2240 5.2 Continuous
16.0 23.6 26.4 621 10060 0.47 79.7 2920 4.7 Continuous
18.0 23.3 36.4 849 11170 0.58 80.2 3630 4.3 Continuous
20.0 23.0 48.6 1120 12180 0.70 79.9 4370 3.9 Continuous
22.0 22.7 62.7 1422 13100 0.82 79.5 5140 3.6 Continuous
24.0 22.7 62.6 1418 13110 0.82 79.1 5080 3.6 Continuous

All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous" region should not cause motor or ESC overheating when using the Default or Pro Kits.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the Performance Kit.
Performance in the "Continuous*" region is classified as intermittent when not using the Performance Kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.