Vertiq 60-08 660Kv

P14x4.8R 24V

Philadelphia, PA USA | 15m | 27.6 C | 30.02 in Hg | 45.8% Humidity

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Speed (RPM) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W) State of Operation
2.0 24.2 0.3 6 1160 0.01 19.7 50 8.0 Continuous
4.0 24.2 1.0 24 2500 0.04 44.8 220 9.0 Continuous
6.0 24.1 2.6 63 3820 0.10 62.6 560 8.9 Continuous
8.0 24.1 5.5 131 5110 0.18 72.2 1030 7.8 Continuous
10.0 24.0 9.8 235 6370 0.28 78.3 1640 7.0 Continuous
12.0 23.8 15.9 378 7580 0.39 81.2 2330 6.2 Continuous
14.0 23.6 24.3 574 8710 0.52 82.9 3160 5.5 Continuous
16.0 23.4 35.1 820 9790 0.67 83.5 4030 4.9 Continuous
18.0 23.0 48.2 1111 10770 0.82 83.2 4930 4.4 Continuous
20.0 22.7 63.7 1442 11650 0.98 82.5 5820 4.0 Continuous*
22.0 22.3 77.0 1718 12230 1.09 81.3 6480 3.8 Continuous*
24.0 22.3 76.8 1712 12210 1.09 81.4 6480 3.8 Continuous*

All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous" region should not cause motor or ESC overheating when using the Default or Pro Kits.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the Performance Kit.
Performance in the "Continuous*" region is classified as intermittent when not using the Performance Kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.