Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Speed (RPM) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W) State of Operation
1.0 24.2 0.1 2 420 0.01 13.8 20 8.7 Continuous
2.0 24.2 0.4 10 1090 0.04 45.1 130 12.9 Continuous
3.0 24.2 1.2 29 1740 0.10 61.1 350 11.9 Continuous
4.0 24.1 2.8 67 2370 0.19 70.2 720 10.7 Continuous
5.0 24.1 5.3 127 2980 0.31 75.3 1230 9.7 Continuous
6.0 24.0 8.8 211 3550 0.44 77.9 1830 8.7 Continuous
7.0 23.9 13.4 319 4070 0.59 78.6 2470 7.7 Continuous
8.0 23.8 18.8 447 4560 0.74 79.2 3140 7.0 Continuous
9.0 23.6 25.5 601 5000 0.90 78.7 3870 6.4 Continuous*
10.0 23.4 32.8 769 5390 1.05 77.1 4440 5.8 Continuous*
11.0 23.2 41.2 957 5730 1.20 75.2 5040 5.3 Intermittent
12.0 23.2 42.7 990 5780 1.22 74.4 5090 5.1 Intermittent

All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous" region should not cause motor or ESC overheating when using the Default or Pro Kits.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the Performance Kit.
Performance in the "Continuous*" region is classified as intermittent when not using the Performance Kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.