Vertiq 40-06 770Kv

P14x8R

Philadelphia, PA USA | 15m | 2024-06-26 | 24.1 C | 29.71 in Hg | 53.6% Humidity

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Speed (RPM) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W) State of Operation
2.0 23.9 0.2 4 1420 0.02 52.1 60 13.8 Continuous
4.0 23.9 0.9 22 2840 0.06 78.4 260 11.8 Continuous
6.0 23.9 2.6 62 4110 0.12 84.8 600 9.7 Continuous
8.0 23.8 5.1 121 5170 0.19 86.1 980 8.1 Continuous
10.0 23.7 8.3 197 6050 0.26 84.6 1350 6.9 Continuous
12.0 23.6 12.1 286 6780 0.33 82.1 1700 6.0 Continuous
14.0 23.5 16.6 390 7380 0.39 78.0 2050 5.3 Intermittent
16.0 23.2 22.3 516 7890 0.45 72.3 2350 4.6 Intermittent

All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous" region should not cause motor or ESC overheating when using the Default or Pro Kits.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the Performance Kit.
Performance in the "Continuous*" region is classified as intermittent when not using the Performance Kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.