Vertiq 60-08 150Kv

P24x7.2R

Philadelphia, PA USA | 15m | 28.2 C | 29.95 in Hg | 35.5% Humidity

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Speed (RPM) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W) State of Operation
2.0 48.2 0.0 2 260 0.01 13.9 10 4.2 Continuous
4.0 48.2 0.1 4 520 0.03 35.5 60 13.8 Continuous
6.0 48.2 0.2 8 790 0.05 53.1 140 16.7 Continuous
8.0 48.2 0.3 16 1060 0.09 65.0 270 17.0 Continuous
10.0 48.2 0.6 28 1330 0.15 72.2 450 16.0 Continuous
12.0 48.2 1.0 46 1600 0.21 76.8 670 14.4 Continuous
14.0 48.1 1.5 72 1860 0.29 79.9 950 13.3 Continuous
16.0 48.1 2.1 102 2110 0.38 81.7 1230 12.0 Continuous
18.0 48.1 2.9 140 2360 0.47 82.8 1580 11.3 Continuous
20.0 48.1 3.9 186 2590 0.57 83.0 1910 10.3 Continuous
22.0 48.1 4.9 235 2810 0.66 83.0 2260 9.6 Continuous
24.0 48.0 6.1 294 3020 0.77 82.9 2650 9.0 Continuous
26.0 48.0 7.5 358 3220 0.88 82.6 3040 8.5 Continuous
28.0 47.9 8.9 428 3400 0.99 81.9 3430 8.0 Continuous
30.0 47.9 10.5 503 3570 1.09 81.0 3820 7.6 Continuous*
32.0 47.9 12.2 583 3740 1.19 79.9 4210 7.2 Continuous*
34.0 47.8 13.9 666 3890 1.29 78.7 4550 6.8 Continuous*
36.0 47.8 15.8 754 4030 1.38 77.3 4890 6.5 Intermittent

All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous" region should not cause motor or ESC overheating when using the Default or Pro Kits.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the Performance Kit.
Performance in the "Continuous*" region is classified as intermittent when not using the Performance Kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.