Vertiq 60-08 300Kv

P16x5.4R 48V

Philadelphia, PA USA | 15m | 2024-08-09 | 25.9 C | 29.77 in Hg | 50.4% Humidity

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Speed (RPM) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W) State of Operation
2.0 48.4 0.1 3 480 0.00 7.7 10 3.4 Continuous
4.0 48.3 0.1 7 1030 0.02 24.4 60 8.5 Continuous
6.0 48.3 0.3 15 1630 0.04 41.8 140 9.5 Continuous
8.0 48.3 0.6 28 2220 0.07 56.0 270 9.8 Continuous
10.0 48.3 1.0 48 2810 0.11 65.6 460 9.6 Continuous
12.0 48.3 1.6 76 3380 0.15 71.6 690 9.1 Continuous
14.0 48.3 2.4 115 3950 0.21 76.3 990 8.6 Continuous
16.0 48.2 3.4 162 4500 0.27 79.6 1310 8.1 Continuous
18.0 48.2 4.6 222 5040 0.34 81.6 1680 7.6 Continuous
20.0 48.2 6.0 289 5560 0.42 84.2 2050 7.1 Continuous
22.0 48.1 7.9 383 6060 0.50 83.3 2500 6.5 Continuous
24.0 48.1 9.9 474 6550 0.59 84.8 2920 6.2 Continuous
26.0 48.0 12.1 579 7010 0.67 85.0 3360 5.8 Continuous
28.0 47.9 14.6 700 7440 0.77 85.3 3860 5.5 Continuous
30.0 47.9 17.2 825 7870 0.85 85.0 4270 5.2 Continuous
32.0 47.8 20.2 965 8250 0.95 85.0 4750 4.9 Continuous
34.0 47.7 23.2 1109 8620 1.04 84.6 5190 4.7 Continuous
36.0 47.6 26.5 1264 8970 1.13 84.1 5640 4.5 Continuous*
38.0 47.5 30.1 1432 9290 1.23 83.3 6100 4.3 Continuous*
40.0 47.4 33.7 1597 9590 1.31 82.2 6490 4.1 Intermittent

All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous" region should not cause motor or ESC overheating when using the Default or Pro Kits.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the Performance Kit.
Performance in the "Continuous*" region is classified as intermittent when not using the Performance Kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.