Vertiq 60-08 300Kv

P17x5.8R 48V

Philadelphia, PA USA | 15m | 2024-08-09 | 26.2 C | 29.77 in Hg | 58.1% Humidity

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Speed (RPM) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W) State of Operation
2.0 48.3 0.1 3 480 0.00 7.9 10 3.3 Continuous
4.0 48.3 0.2 7 1030 0.02 26.6 70 9.5 Continuous
6.0 48.3 0.3 16 1620 0.04 45.7 180 11.0 Continuous
8.0 48.3 0.7 31 2210 0.08 58.9 350 11.1 Continuous
10.0 48.3 1.2 56 2790 0.13 69.2 590 10.6 Continuous
12.0 48.3 1.9 91 3360 0.19 74.5 900 9.8 Continuous
14.0 48.3 2.9 140 3920 0.26 76.8 1240 8.9 Continuous
16.0 48.2 4.2 201 4450 0.34 79.7 1650 8.2 Continuous
18.0 48.2 5.6 271 4970 0.43 82.8 2090 7.7 Continuous
20.0 48.1 7.4 357 5470 0.52 83.2 2540 7.1 Continuous
22.0 48.1 9.5 458 5940 0.62 84.0 3030 6.6 Continuous
24.0 48.0 11.8 568 6390 0.72 84.6 3530 6.2 Continuous
26.0 47.9 14.4 689 6820 0.82 84.9 4020 5.8 Continuous
28.0 47.9 17.2 823 7220 0.92 84.3 4520 5.5 Continuous
30.0 47.8 20.3 969 7580 1.03 84.2 5050 5.2 Continuous
32.0 47.7 23.5 1120 7940 1.13 83.6 5530 4.9 Continuous*
34.0 47.6 27.0 1284 8270 1.23 82.9 6010 4.7 Continuous*
36.0 47.5 30.6 1453 8580 1.32 81.8 6460 4.4 Intermittent

All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous" region should not cause motor or ESC overheating when using the Default or Pro Kits.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the Performance Kit.
Performance in the "Continuous*" region is classified as intermittent when not using the Performance Kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.