Vertiq 60-08 660Kv

P17x5.8R 24V

Philadelphia, PA USA | 15m | 27.2 C | 30.03 in Hg | 41.5% Humidity

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Speed (RPM) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W) State of Operation
1.0 24.2 0.1 2 430 0.00 8.9 10 5.1 Continuous
2.0 24.2 0.3 8 1120 0.02 33.2 80 10.4 Continuous
3.0 24.2 0.8 19 1790 0.05 50.0 200 10.3 Continuous
4.0 24.1 1.7 41 2450 0.10 60.4 410 10.0 Continuous
5.0 24.1 3.1 74 3090 0.16 67.7 690 9.3 Continuous
6.0 24.1 5.2 124 3710 0.23 73.2 1070 8.6 Continuous
7.0 24.0 7.8 187 4320 0.32 76.2 1490 8.0 Continuous
8.0 23.9 11.3 270 4910 0.41 78.6 2000 7.4 Continuous
9.0 23.8 15.4 368 5460 0.52 80.4 2520 6.9 Continuous
10.0 23.7 20.4 484 5990 0.62 80.5 3060 6.3 Continuous
11.0 23.6 26.2 617 6490 0.74 81.3 3600 5.8 Continuous
12.0 23.4 32.6 764 6950 0.85 81.1 4150 5.4 Continuous
13.0 23.3 39.8 924 7370 0.96 80.5 4710 5.1 Continuous*
14.0 23.1 47.8 1103 7770 1.08 79.6 5230 4.7 Continuous*
15.0 22.8 56.7 1294 8140 1.19 78.4 5720 4.4 Intermittent
16.0 22.7 63.2 1433 8370 1.26 77.2 6040 4.2 Intermittent

All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous" region should not cause motor or ESC overheating when using the Default or Pro Kits.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the Performance Kit.
Performance in the "Continuous*" region is classified as intermittent when not using the Performance Kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.