Vertiq 81-08 G2 140Kv

SR22x6.6

Philadelphia, PA USA | 15m | 2025-02-06 | 23.2 C | 29.83 in Hg | 28.2% Humidity

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Speed (RPM) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W) State of Operation
2.0 48.0 0.1 4 250 0.00 3.1 20 5.1 Continuous
4.0 48.0 0.1 6 520 0.02 13.1 60 9.2 Continuous
6.0 48.0 0.2 11 790 0.03 26.2 130 11.8 Continuous
8.0 48.0 0.4 18 1080 0.07 40.7 240 13.2 Continuous
10.0 48.0 0.6 29 1360 0.11 52.8 410 14.0 Continuous
12.0 47.9 0.9 45 1650 0.16 62.4 610 13.6 Continuous
14.0 47.9 1.4 67 1930 0.23 68.5 860 12.9 Continuous
16.0 47.9 2.0 95 2210 0.30 73.4 1150 12.1 Continuous
18.0 47.9 2.6 127 2480 0.38 77.6 1460 11.5 Continuous
20.0 47.8 3.5 168 2750 0.46 78.9 1790 10.7 Continuous
22.0 47.8 4.5 214 3010 0.55 81.8 2150 10.1 Continuous
24.0 47.8 5.6 266 3260 0.65 82.7 2490 9.3 Continuous
26.0 47.7 6.8 324 3500 0.74 83.5 2860 8.8 Continuous
28.0 47.7 8.1 387 3740 0.83 83.8 3230 8.4 Continuous
30.0 47.6 9.6 459 3970 0.94 85.1 3680 8.0 Continuous
32.0 47.6 11.2 533 4190 1.04 85.7 4050 7.6 Continuous
34.0 47.5 12.8 611 4400 1.13 85.1 4420 7.2 Continuous
36.0 47.5 14.7 699 4600 1.24 85.8 4850 6.9 Continuous
38.0 47.4 16.6 790 4800 1.35 85.7 5270 6.7 Continuous
40.0 47.4 18.7 888 4980 1.45 84.9 5700 6.4 Continuous
42.0 47.3 20.9 988 5160 1.56 85.4 6090 6.2 Continuous
44.0 47.3 23.2 1095 5320 1.67 84.8 6530 6.0 Continuous
46.0 47.2 25.5 1202 5490 1.76 84.4 6900 5.7 Continuous
48.0 47.2 26.6 1257 5600 1.80 84.2 7050 5.6 Continuous
48.0 47.2 26.6 1257 5600 1.80 84.2 7050 5.6 Continuous*

All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous" region should not cause motor or ESC overheating when using the Default or Pro Kits.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the Performance Kit.
Performance in the "Continuous*" region is classified as intermittent when not using the Performance Kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.