Vertiq 81-08 G2 240Kv
MEJ 24x8.1R
Philadelphia, PA USA | 15m | 2025-03-05 | 25.1 C | 29.53 in Hg | 35.4% Humidity
Commanded Voltage (V) | Supply Voltage (V) | Supply Current (A) | Input Power (W) | Torque (Nm) | Motor-Controller Efficiency (%) | Thrust (g) | Propulsion Efficiency (g/W) | Speed (RPM) | State of Operation |
---|---|---|---|---|---|---|---|---|---|
2.0 | 24.2 | 0.2 | 4 | 0.02 | 16.1 | 50 | 11.6 | 400 | Continuous |
4.0 | 24.2 | 0.6 | 15 | 0.08 | 48.1 | 250 | 16.7 | 870 | Continuous |
6.0 | 24.2 | 1.6 | 39 | 0.19 | 68.4 | 610 | 15.8 | 1340 | Continuous |
8.0 | 24.1 | 3.5 | 85 | 0.34 | 76.5 | 1130 | 13.4 | 1800 | Continuous |
10.0 | 24.1 | 6.4 | 154 | 0.53 | 80.4 | 1770 | 11.5 | 2230 | Continuous |
12.0 | 23.9 | 10.2 | 244 | 0.73 | 83.0 | 2450 | 10.0 | 2640 | Continuous |
14.0 | 23.8 | 15.3 | 364 | 0.98 | 84.2 | 3270 | 9.0 | 3000 | Continuous |
16.0 | 23.7 | 21.3 | 505 | 1.21 | 84.3 | 4040 | 8.0 | 3360 | Continuous |
18.0 | 23.5 | 28.7 | 673 | 1.46 | 83.6 | 4860 | 7.2 | 3680 | Continuous |
20.0 | 23.3 | 36.6 | 853 | 1.69 | 82.3 | 5610 | 6.6 | 3970 | Continuous |
22.0 | 23.1 | 46.2 | 1066 | 1.94 | 80.5 | 6430 | 6.0 | 4220 | Continuous* |
24.0 | 23.0 | 48.8 | 1123 | 2.02 | 80.7 | 6710 | 6.0 | 4280 | Intermittent |
All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the performance kit.
Performance in the "Continuous*" region is classified as intermittent when not using the performance kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.