Vertiq 81-08 G2 240Kv

P19x5.7R

Philadelphia, PA USA | 15m | 2025-03-05 | 23.4 C | 29.79 in Hg | 32.2% Humidity

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W) Speed (RPM) State of Operation
2.0 48.4 0.1 5 0.00 4.0 10 2.1 370 Continuous
4.0 48.4 0.2 11 0.02 15.9 70 6.3 840 Continuous
6.0 48.5 0.5 23 0.05 29.3 190 8.3 1340 Continuous
8.0 48.4 0.8 41 0.09 41.5 370 9.1 1840 Continuous
10.0 48.4 1.4 66 0.14 51.9 600 9.2 2330 Continuous
12.0 48.4 2.0 98 0.20 60.6 890 9.1 2800 Continuous
14.0 48.4 3.0 144 0.28 66.0 1230 8.6 3270 Continuous
16.0 48.3 4.1 200 0.36 70.4 1620 8.1 3740 Continuous
18.0 48.3 5.5 266 0.45 73.9 2030 7.6 4190 Continuous
20.0 48.2 7.3 350 0.55 75.7 2470 7.1 4620 Continuous
22.0 48.2 9.1 441 0.65 78.6 2970 6.7 5050 Continuous
24.0 48.1 11.5 551 0.77 79.5 3480 6.3 5450 Continuous
26.0 48.0 13.9 668 0.89 81.1 4030 6.0 5840 Continuous
28.0 47.9 16.7 800 1.01 82.0 4580 5.7 6230 Continuous
30.0 47.8 19.8 947 1.14 82.8 5180 5.5 6590 Continuous
32.0 47.7 23.0 1099 1.26 83.0 5740 5.2 6910 Continuous
34.0 47.6 26.5 1263 1.39 83.0 6280 5.0 7220 Continuous
36.0 47.5 30.3 1440 1.51 82.6 6830 4.7 7530 Continuous
38.0 47.4 34.2 1622 1.64 82.6 7420 4.6 7820 Continuous
40.0 47.3 38.2 1807 1.76 82.7 7960 4.4 8110 Continuous*
42.0 47.2 42.4 2001 1.87 81.6 8380 4.2 8360 Continuous*
44.0 47.0 47.3 2222 1.99 80.5 8990 4.0 8580 Continuous*
46.0 46.9 51.9 2432 2.12 80.4 9510 3.9 8820 Intermittent
48.0 46.8 53.6 2510 2.15 79.5 9600 3.8 8880 Intermittent

All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the performance kit.
Performance in the "Continuous*" region is classified as intermittent when not using the performance kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.