Vertiq 81-08 G2 240Kv

P20x6R

Philadelphia, PA USA | 15m | 2025-02-12 | 23.4 C | 30.23 in Hg | 23.8% Humidity

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Speed (RPM) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W) State of Operation
2.0 48.0 0.1 5 370 0.00 3.7 20 4.0 Continuous
4.0 48.0 0.3 12 840 0.02 16.7 90 7.5 Continuous
6.0 48.0 0.5 25 1340 0.06 32.2 220 8.8 Continuous
8.0 48.0 0.9 45 1830 0.11 46.8 440 9.8 Continuous
10.0 47.9 1.6 76 2310 0.18 57.7 740 9.7 Continuous
12.0 47.9 2.5 120 2780 0.27 66.0 1140 9.5 Continuous
14.0 47.9 3.7 177 3240 0.38 71.9 1590 9.0 Continuous
16.0 47.8 5.2 250 3680 0.49 75.3 2080 8.3 Continuous
18.0 47.8 7.2 343 4110 0.62 77.6 2650 7.7 Continuous
20.0 47.7 9.3 443 4520 0.75 80.0 3210 7.3 Continuous
22.0 47.6 11.8 562 4920 0.89 81.5 3780 6.7 Continuous
24.0 47.6 14.5 690 5290 1.03 82.6 4390 6.4 Continuous
26.0 47.5 17.7 839 5630 1.18 83.2 5050 6.0 Continuous
28.0 47.4 21.1 1001 5950 1.33 83.1 5690 5.7 Continuous
30.0 47.3 24.9 1178 6260 1.50 83.6 6380 5.4 Continuous
32.0 47.1 28.8 1356 6560 1.64 83.2 6960 5.1 Continuous
34.0 47.0 32.7 1536 6840 1.78 83.0 7520 4.9 Continuous*
36.0 46.9 37.1 1740 7110 1.92 82.2 8090 4.6 Continuous*
38.0 46.8 41.8 1954 7330 2.08 81.6 8720 4.5 Intermittent
40.0 46.6 46.8 2180 7580 2.21 80.5 9290 4.3 Intermittent
42.0 46.4 52.7 2448 7750 2.38 79.0 10060 4.1 Intermittent
44.0 46.2 58.8 2721 7960 2.50 76.7 10460 3.8 Intermittent
46.0 46.1 64.8 2984 8100 2.63 74.7 11000 3.7 Intermittent
48.0 46.0 64.6 2974 8110 2.61 74.5 10900 3.7 Intermittent

All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous" region should not cause motor or ESC overheating when using the Default or Pro Kits.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the Performance Kit.
Performance in the "Continuous*" region is classified as intermittent when not using the Performance Kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.